Name | Composition | Parameters | Qty. | remark |
---|---|---|---|---|
1 Concrete Batcher PLD1200-III |
Bin | 2m 3 | 3Pc | Accuracy ± 2% |
Measure hopper | 2000kg | 1Pc | ||
measure Sensor | XYL-1 | 1Pc | ||
Belt | B500 | 4pc | ||
2 Main body |
Concrete Mixer | JS750 | 1set | Accuracy ± 1% |
Cement measure system | max. 400kg | 1set | ||
Water measure system | max. 200kg | 1set | Accuracy ± 1% |
|
Additive(liquid) measure system | max. 40kg | 1set | Accuracy ± 1% |
|
Steel structure | 1set | Discharging 3.8m | ||
Lifting motor | 1pc | |||
Lift orbit | 1set | |||
Liftinghopper | 1set | |||
3 Water Supply System |
Water Tank | 2.5m 3 | 1pc | |
Water pump | 3kW | 1pc | ||
Control valve for water | DF-50F | 1pc | ||
pipeline | 1set | |||
4 Additives Supply System |
Additive (liquid) tank | 2.5m 3 | 1pc | |
Pump | BW6-16 | 1 set |
||
pipeline | 1set | |||
Gas arch breaking preventing sedimentation | 1set | |||
5 Pneumatic System |
Pneumatic pump | 1set | ||
pipeline | 1set | |||
Additional parts | 1set | |||
6 Control System |
Control room | 7m 2 | 1set | |
controlling software | HBK50 | 1set | ||
PLC | CQM1H | 1set | ||
Relay |
MY2 | 1set | ||
Lap joint | LC1-D | 1set | ||
Aerotherapeutics | GV2 | 1set | ||
Button | XB2-BW | 1set | ||
Control table | 1set | |||
Printer | LQ300 | 1pc | ||
Air -condition | 1pc | |||
computer | 1pc | |||
7 | Screw Conveyor | LSY219-9 | 1set | |
8 | Assembly Cement silo | PSC100A Discharging height 3.32m |
1set |